A SERVICE OF

logo

Vehicle Mounted DC Single Dock 7-19
2325A137REFGD Revision B 2325 Reference Guide
Caution:
Correct electrical polarity and grounding is required for safe
and proper installation.
Only connect to a negative ground DC supply circuit.
Not for installation to positive ground circuits.
When the Singledock is connected to an unswitched outlet on the fuse
box the 2325 battery will always receive a charge from the vehicle
battery. If the unit is left turned on for extended periods of time, the
2325 could drain the vehicle battery.
If the Singledock is connected to a switched outlet on the fuse box the
2325 and battery will only charge when the vehicle is on. This will
eliminate the problem of draining the vehicle battery.
Fuse Replacement
The unit uses a 250V, 1.5A (fast blow), high current interrupting rating
fuse that is externally accessible and user replaceable. Should it need
replacement, replace with same size, rating and type of fuse (such as
Bussman AGC-1 1/2).
LXE Vehicle Bracket
Install the Bottom Mounting Bracket portion of the mounting assembly
to the vehicle using ¼” (6.35mm) maximum diameter fasteners (not
supplied by LXE).
Figure 7-9 Bottom Mounting Bracket