3-51CrossPoint 450 Plus and MAV Plus Switchers • Operation
Selecting the rear panel Remote port protocol and baud rate
This procedure affects the rear panel Remote port only. The front panel
Configuration (RS-232) port’s variables can be changed under serial port or
Ethernet control only. See the Command/Response table for IP SIS commands,
in chapter 4, “Programmer’s Guide”, to configure either port under SIS
control.
The Remote port settings are protected when front panel lock mode 2 is
selected. You can view the settings in lock mode 2, but not adjust them from
the front panel.
The switcher can support either RS-232 or RS-422 serial communication protocol,
and operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these
variables can be viewed and changed from the front panel.
View and configure the switcher’s serial communications settings as follows:
1. To enter Serial Port Configuration mode, simultaneously press and hold all
Control buttons (Enter, Preset, View, and Esc) (figure 3-79).
The flashing Control button indicates the baud rate as follow
Enter — 9600 Preset — 19200
View — 38400 Esc — 115200
The flashing I/O button indicates the protocol as follows:
RGBHV/Video — RS-232 Audio — RS-422/RS-485
In this example, the port is set to RS-232 at 9600 baud.
ress and hold the Enter, Preset,
iew, and Esc buttons.
All Control buttons light with
one flashing.
Both I/O buttons ligh
with one flashing.
2 seconds
I / O
RGBHV AUDIO
C O N T R O L
PRESET
ENTER
ESCVIEW
•
•
C O N T R O L
PRESET
ENTER
ESCVIEW
Figure 3-79 — RS-232/RS-422 and baud rate display
2. Release the Control buttons.