ADCP-75-210 • Issue 1 • March 2007
Page 11
© 2007, ADC Telecommunications, Inc.
Figure 7 is a schematic showing the data flow in the RAN chassis, as represented by the PCS-A
band. As shown, data flows in two directions, from the Hub through the RAN to the antenna,
and from the antenna through the RAN back to the Hub. In each direction, data conversion
occurs, with optical data “upconverted” to RF data in the up direction in the schematic, and RF
data “downconverted” to optical data in the down direction. In an up direction, the RUC module
converts Digitized Intermediate Frequency (DIF) data into PCS, Cellular, and SMR frequency
RF bands. The RF signals are amplified and then transmitted from the RF antenna. In the down
direction, the RDC module converts PCS, Cellular, and SMR frequency bands into DIF data.
The overall series of events is managed by the CPU using an Ethernet connection to the chassis
backplane.
Figure 7. RAN Chassis Schematic
6 RAN Down Converter (RDC or RDC2) Section 1.7.6 on Page 17
7 RAN Up Converter (RUC2.X or RUC3) Section 1.7.7 on Page 19
8 800 MHz Multi-Coupler Section 1.7.9 on Page 20
9 1900 MHz Multi-Coupler Section 1.7.10 on Page 22
10 Fan Access Panel Section 1.7.8 on Page 20
Table 3. RAN Chassis Electronic Modules
REF # MODULE NAME FOR DETAILS REFER TO
SIF
Pri Div
Pri Div
1900
MUL
DIF
DIF
RF
1900-P 1900-D
DIF
RUC RDC
CPU
Ethernet
Fiber Fiber
MCPA
RAN
H
U
B
MB
ANT
RAN = Radio Access Node
DIF = Digital Intermediate
Frequency
SIF = Synchronous Interface
RUC = RAN Up Converter
MCPA = Munti-Carrier Power
Amplifier
MB ANT = Multi Band Antenna
MUL = Multi-Coupler
RDC = RAN Down Converter
21777-A
ABFRX
ANT
PCS QUADPLEXER
DECRX
ANT
PCS QUADPLEXER
66