![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/a1/4a1bb5e3-fbdb-4eff-9c71-f976df3bde1c/4a1bb5e3-fbdb-4eff-9c71-f976df3bde1c-bg12.png)
ADCP-75-210 • Issue 1 • March 2007
Page 6
© 2007, ADC Telecommunications, Inc.
1.5 Dimensions and Specifications
Figure 5. NXD RAN Dimensions
Table 2. RAN Specifications
ITEM SPECIFICATION COMMENT
Physical and Mechanical
Dimensions (HxWxD) 36.5 x 31.0 x 24.0 inches
(92.7 x 78.7 x 60.1 cm)
See also Figure 5
Weight
with extended batteries (4)
300 lbs. (136.4 kg)
625 lbs. (284.1 kg)
RAN without batteries
Total RAN + 4 batteries
Color Putty white
Bands per box
Up to 4
Boxes per RAN site
Up to 2 RANs
RF connections
RAN cabinet has
5 Type N plugs
Cable type: CommScope PN
540ANM or equivalent
Environmental and Thermal
Box thermal management External air Variable speed fans (PIC/PA
Assembly and cPCI)
Operating temperature -40 to +50 degrees C -40 to 122 degrees F
Cold-start temperature -20 to +50 degrees C -4 to 122 degrees F
Storage temperature -40 to +85 degrees C -40 to 185 degrees F
Internal air temperature 0 to 60 degrees C 32 to 140 degrees F
Weather resistance NEMA-3R
Operational humidity 95%
Acoustic emissions 63 dBA
21228-A
36.5 IN.
(92.7 CM)
31.0 IN.
(78.7 CM)
24.0 IN.
(60.1 CM)
FRONT SIDE