Sterling AF-XXX Wheelchair User Manual


 
Additive Feeders Chapter 4: Operation 22 of 55
Chapter 4: Operation
4-1 Start-up
1. Turn the power switch ON.
2. Set the desired feed rate on the RPM display using the up or down arrows.
3. Flip the motor switch to AUTO.
If the additive feeder is installed correctly, it should begin operation at the desired RPM when
the processing machine screw is in operation.
4-2 Controller Description and Operation
Identifying Control Panel Indicator Lights and Switches on the Controller
Switches
Power Switch. This switch turns the control ON and OFF.
Motor Switch. This switch has three (3) positions:
OFF stops the auger motor.
AUTO starts normal automatic operation.
MANUAL operates the auger at the set point as long as the switch is held in this
position. Use this feature when calibrating the feeder or during cleanout.
Indicator Lights
Motor Light. This indicator lights when the auger motor is turning.
Auger Speed. This LED displays the auger speed setpoint.
Timer/Counter Control Operation (Injection Molding Applications)
The Timer/Counter control is designed for use with cyclical processes like injection molding
and features a timer and counter module. It also acts as a cycle override safety timer.
Timer Module
This feature of the controller assists in calibration of the additive feeder (See Page 19 for
specific calibration instructions).
Procedure
1. Set the timer to the desired calibration period, using the round timer keys (See the
timer information sheet for additional information).
2. Start the additive feeder by flipping the MOTOR switch to the MANUAL position.
3. When the timer times out, the feeder automatically stops.
Used as a Cycle Override Safety Timer
This component of the controller allows the operator to override the molding machine shot
cycle when the additive feeder motor is running in AUTO mode.