RayTek FR Thermometer User Manual


 
Accessories
38 MarathonSeriesFA/FR
8.6IndustrialPowerSupply
TheDINrailmountindustrialpowersupplytransformsaninputvoltageof85264VACintoan
outputvoltageof24VDC/1.25A.Thepowersupplyprovidesshortcircuitandoverloadprotection.
Topreventelectricalshocks,thepowersupplymustbeusedinprotectedenvironments
(cabinets)!
Technicaldata:
Protectionclass classIIasperIEC/EN61140
Environmentalprotection IP20
Operatingtemperaturerange‐25°Cto70°C(13°Fto158°F)
ACInput L,N
wiresize:0.5to2mm²(AWG24to
12)
DCOutput +‒
wiresize:0.5to2mm²(AWG24to12)
Figure35:DimensionofIndustrialPowerSupply