SensorLocation
14 MarathonSeriesFA/FR
4.5SensorPlacement(1‐ColorMode)
Optical head placement for one‐color temperature measurements is more critical than two‐color
measurements.Thesensormusthaveaclearviewofthetarget.Therecanbenoobstructionsonthe
lens, window, or in the atmosphere. The distance from the target can be anywhere beyond the
minimumrequirements,as
longasthetargetcompletelyfillsthefieldofview.Thefollowingfigure
illustratesproperplacementwhenusingtheone‐colormode.
Figure10:ProperSensorPlacementin1‐ColorMode
4.6SensorPlacement(2‐ColorMode)
Thefollowingfigureshowsheadplacementundervariousconditionswheretwo‐colortemperature
measurements can be taken. Note, however, that if the sensor signal is reduced more than 95%
(includingemissivityandobscurationofthetarget),thesensoraccuracyalsodegrades.
Tar
g
et
g
reater than spot size
Tar
g
et equal to spot size
Tar
g
et smaller than spot size
best good incorrect