KitchenAid W101871170D Oxygen Equipment User Manual


 
9
Maximum Length of Vent System
To calculate the length of the system you need, add the equivalent
feet (meters) for each vent piece used in the system.
Example Vent System
The following example falls within the maximum vent length of
35 ft (8.9 m).
Install Vent System
1. Place cardboard or similar material on top of a flat surface
where you can easily assemble the downdraft vent system.
2. Remove parts packages, downdraft vent and blower box from
the carton.
3. Remove all shipping materials, tape and film from the
downdraft vent and blower box.
4. Remove screws from each side of the vent. Attach the left and
right side overcounter support brackets to the downdraft vent
and push up to align the screw holes. Use screws to secure
the brackets.
5. Attach the left and right side end caps to the downdraft vent.
Place the end cap upon the overcounter support, slide the tab
into the slot and snap into place over the plastic tabs.
Vent Length
6" (15.2 cm) round 35 ft (8.9 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 35 ft (8.9 m)
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
6" (15.2 cm)
wall cap
0.0 ft
(0.0 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) transition
4.5 ft
(1.4 m)
6" (15.2 cm) to 3¹⁄₄" x 10"
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
transition
5.0 ft
(1.5 m)
6" (15.2 cm) to 3¹⁄₄" x 10"
(8.3 cm x 25.4 cm) 90° elbow
transition
5.0 ft
(1.5 m)
A. Blower motor
B. Transition
C. 90° elbows
D. 6" backdraft damper (supplied)
A
B
C
6 ft
(1.8 m)
2 ft (0.6 m)
D
2 - 90° elbow = 10.0 ft (3 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Transition = 4.5 ft (1.4 cm)
Length of 6" (15.2 cm) system = 22.5 ft (6.8 m)
A. Overcounter support bracket
B. Blower motor box
C. Overcounter support bracket screw
A.End cap