KitchenAid W101871170D Oxygen Equipment User Manual


 
20
4. Attach 1 undercounter bracket on front upper right corner of
downdraft vent with slot over vent mounting hole and flange
against countertop. Attach other bracket to left side of the
downdraft vent. Drill starter holes through undercounter
mounting brackets into the underside of the countertop. Insert
appropriate length screws into holes and tighten brackets to
the countertop.
Electrical Connection
1. Disconnect power.
2. Feed the home power supply cable through the conduit
connector and into the terminal box.
3. Remove vent box knockout and install a UL listed or CSA
approved conduit connector. Feed exterior-mounted vent
motor wiring through conduit connector.
4. Attach the green (or green and yellow) ground wires from the
home power supply cable and the exterior-mounted vent
motor wiring to the green ground screw.
IMPORTANT: Exterior vent motor wires must be connected in
the terminal box as shown.
5. Connect the 2 blue wires together using UL listed wire
connectors.
6. Connect the 2 brown wires together using UL listed wire
connectors.
A.When attaching undercounter bracket to underside
of countertop, make sure that the screw length will
not go through countertop when tightened.
B. Backsplash
C. Countertop
A
B
C
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A.Green or green and yellow ground wires
B.Green ground screw
C. Blue wires
D.UL listed wire connector
E. Brown wires
F. Downdraft vent wiring
G. Black wires
H. White wires
I.UL listed or CSA approved conduit and connector,
(Home power supply cable).
J.UL listed or CSA approved conduit and connector,
(Exterior-mounted vent motor wiring).
A
B
H
D
G
C
E
F
I
J
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.