GE A071-0CG Sleep Apnea Machine User Manual


 
GE Energy Services
ANSI X3.28/SRIO DPA
CONFIGURATION GUIDE
A071-0CG-2.02-2 Restricted
12
Full
Can't allocate rx sinks
Cause:
Not enough RAM available for the receive buffer queue to be created.
Remedy:
Reduce the amount of memory used by this or other applications in the system.
Upgrade to a larger memory model.
Can't create required exchanges. Suspending
Cause:
The system cannot create the external interface inter-process message exchange.
Remedy:
Contact the Customer Service Department to report this error.
Can't create T071 exchange
Cause:
The system cannot create the external interface inter-process message exchange.
Remedy:
Contact the Customer Service Department to report this error.
Can't get enough memory for ANSI Application. Suspending
Cause:
The system cannot retrieve enough ram for operation of the ANSI DPA.
Remedy:
Reduce the amount of memory used by this or other applications in the system.
Upgrade to a larger memory model.
Can't allocate memory for event queue. Suspending !
Cause:
The system cannot retrieve enough ram for operation of the ANSI DPA.
Remedy:
Reduce the amount of memory used by this or other applications in the system.
Upgrade to a larger memory model.
Can't open communications port
Cause:
The system has found that this port is invalid, or already in use by another process.
Remedy:
Ensure the Port configured in A071MAIN contains a valid port name.
Ensure the Port configured in A071MAIN is not in use by another application.