BenQ SP920P Thermometer User Manual


 
50
Maintenance
English
Indicators
Light Status & Description
POWER TEMP LAMP1 LAMP2
Power events
Orange Off Off Off
Stand-by mode.
Green
Flashing
Off Off Off
Powering up.
Green Off Off Off
Normal operation.
Orange
Flashing
Off Off Off
1. The projector needs 90 seconds to cool down as it was
abnormally shut down without the normal cooling
down process. Or
2. The projector needs to cool for 90 seconds after the
power is turned off.
Orange
Flashing
Off Off Off
The projector has shutdown automatically. If you try to re-
start the projector, it will shutdown again. Please contact
your dealer for assistance.
Orange
Flashing
Off Red Off
Lamp events
Off Off Red Off
Lamp 1 failed. The projector has entered Single-Alternative
mode automatically. Replace lamp 1 as soon as possible.
Off Off Off Red
Lamp 2 failed. The projector has entered Single-Alternative
mode automatically. Replace lamp 2 as soon as possible.
Off Off Red Red
The projector has shutdown automatically. If you try to re-
start the projector, it will shutdown again. Please contact
your dealer for assistance.
Thermal events
Off Red Off Off
The projector has shutdown automatically. If you try to re-
start the projector, it will shutdown again. Please contact
your dealer for assistance.
Off Red Red Off
Off Red Green Off
Off Red Orange Off
Off Red Off Red
Off Red Off Green
Off Red Off Orange
Red Red Red Off
Red Red Green Off
Red Red Orange Off
Green Red Red Off