BenQ SP920P Thermometer User Manual


 
39
Operation
English
Setting the lamp mode
This projector is capable of dual-lamp projection and provides three lamp modes for different purposes:
You can perform the following steps to choose a lamp mode according to your preference.
1. Press MENU/EXIT and then press / until the SYSTEM SETUP: Advanced menu is highlighted.
2. Press to highlight Lamp Settings and press ENTER.
3. Press to highlight Lamp Mode and press ENTER.
4. Press to highlight your preferred lamp mode and press ENTER.
5. A confirmation message displays. Highlight Ye s and press ENTER.
If one lamp fails, the projector enters Single-Alternative mode automatically. Dual-Brightest and Dual-
Reliable settings are not available.
After switching from Dual-Brightest/Dual-Reliable mode to Single-Alternative mode or vice versa, wait
for 90 seconds before you can adjust the lamp mode again.
Setting the projector in Dual-Reliable mode extends the lamp timer automatic shutdown feature. See
"Setting Lamp Mode as Dual-Reliable" on page 47 for details.
Personalizing the On-Screen Display (OSD) menus
The On-Screen Display (OSD) menus can be set according to your preferences. The following settings do not
affect the projection settings, operation, or performance.
Menu Display Time in the SYSTEM SETUP: Advanced > Menu Settings menu sets the length of time the
OSD will remain active after your last key press. The time length ranges from 5 to 30 seconds in 5-second
increments. Use / to select a suitable time.
Menu Position in the SYSTEM SETUP: Advanced > Menu Settings menu sets the OSD position in five
locations. Use / to select a preferred position.
Language in the SYSTEM SETUP: Basic menu sets your familiar language for the On-Screen (OSD) Menus.
Use / to select your language.
Splash Screen in the SYSTEM SETUP: Basic menu sets a preferred logo screen to be displayed during
projector start-up. Use / to select a screen.
Lamp mode User Benefit Suitable environment
Dual-Brightest
(Two lamps are used in normal
mode)
Delivering super-bright and clear images
Suitable for high-ambient-light environments
Allowing continous and non-stop operation
under critical situations
Large, well lit meeting
rooms or auditoriums
Dual-Reliable
(Two lamps are used in
economic mode)
Extending the lamp life
Allowing continous and non-stop operation
under critical situations
Mid-large boardrooms
Single-Alternative
(The lamp with shorter operating
hours is selected automatically
and used in normal mode)
Extending the total operation time
Reducing lamp replacement frequency
Normal sized rooms