Agilent Technologies 6811B Pacemaker User Manual


 
17
The front panel menus - at a glance
Press to change the ac source’s selected
interface from remote operation to local (front
panel) operation. Pressing the key will have no
effect if the interface state is already Local, Local-
with-Lockout, or Remote-with-Lockout.
Error
Error Functions
ERROR <value> Displays system error codes stored in the SCPI
error queue. If no errors exist, a 0 is displayed.
The Err annunciator is lit when there are errors.
Address Functions
ADDRESS <value> sets the GPIB address
INTF GPIB | RS232 selects an interface
BAUDRATE 300 | 600 | 1200
2400 | 4800 | 9600
selects the baud rate
PARITY NONE | EVEN | ODD selects message parity
LANG SCPI | E9012 selects the language
NOUTPUTS 1 | 3 selects the number of outputs
1
Save
Save Functions
Press to save an existing ac source state in nonvolatile memory.
Up to 16 states can be saved (0-15).
Recall Functions
Press to place the ac source into a previously saved state.
Up to 16 states can be recalled (0-15).
First press and release this blue shift key to select
a shifted function. The Shift annunciator lights
when this key is pressed.
Harmonic
Harmonic Functions
<
reading>A I:MAG: <index> current harmonic magnitude
<
reading>° I:PHASE: <index>
current harmonic phase
<
reading>V V:MAG: <index> voltage harmonic magnitude
<
reading>° V:PHASE: <index>
voltage harmonic phase
<
reading> N:MAG: <index> neutral current harmonic magnitude
<
reading>° N:PHASE: <index>
neutral current harmonic phase
<
reading> CURR:THD current total % harmonic distortion
<
reading> VOLT:THD voltage total % harmonic distortion
Meter functions continued on next column
Meter Functions
<reading>V <reading>Hz rms voltage and frequency
<reading>V <reading>A rms voltage and rms current
<reading>A <reading>Hz rms current and frequency
<reading>V <reading>W rms voltage and power
<reading> CREST F current crest factor
<reading>A PK REP peak current, repetitive
<reading>A PK NR peak current, nonrepetitive
<reading>VA apparent power
<reading> VAR reactive power
<reading>W TOTAL total power all phases
1
<reading> PFACTOR power factor
<reading>A NEUTRAL neutral rms current
1
Output
Output Functions
OUTP:COUP AC | DC select output coupling
3
*RST executes the *RST command
TTLT:SOUR BOT| EOT| LIST select Trigger Out source coupling
TTLT:STATE ON | OFF set Trigger Out state
IMP:STATE ON | OFF set output impedance programming
3
IMP:REAL <value> set real part of output impedance
3
IMP:REAC <value> set reactive part of output impedance
3
PON:STATE RST | RCL0 select power-on state command
RI LATCHING | LIVE | OFF sets remote inhibit mode
DFI ON | OFF sets discrete fault indicator state
DFI:SOUR QUES | OPER
ESB | RQS | OFF
select the DFI source
Input Functions
INP:COUP AC | DC | ACDC choose meter coupling
CURR:RANGE HIGH | LOW current measurement range
3
WINDOW KBESSEL | RECT select harmonic measurement
window meter
Status
Status Functions
*CLS executes the *CLS command
STATUS:PRESET executes STATus:PRESet command
*ESR? <value> return Event Status register value
*STB <value> return Status Byte register value
OPER:EVEN? <value> return STAT:OPER:EVENT? value
OPER:COND <value> return STAT:OPER:COND? value
QUES:EVEN? <value> return STAT:QUES:EVENT? value
QUES:COND <value> return STAT:QUES:COND? value
Protect Functions
PROT:CLEAR clears latched protection signal
CURR:PROT ON | OFF set overcurrent protection function
VOLT:PROT ON | OFF set overvoltage protection function
3
VOLT:PROT <value> set overvoltage protection level
DELAY <value> set a time delay for activating a
protection fault
Local
Address
Recall
Meter
Input
Prot
SYSTEM Keys
FUNCTION Keys
FUNCTION Keys