A&D HV-60KV-WP Scale User Manual


 
HV-WP/HW-WP Series Page 25
10. Accumulation Function
10.
10.10.
10. Accumulation Function
Accumulation FunctionAccumulation Function
Accumulation Function
This function counts the number of weighed items, calculates the total mass value
and can display the number and accumulated mass value.
Set the parameters of the "accumulation function ( f8 )" in the function table, in
advance, to use this function.
Set the parameters of the "print mode ( f9 )" in the function table, in advance, to use
the built-in printer.
Operation and Switches
The display of the accumulation count has a blinking without a unit.
The display of the accumulation value has a unit and a blinking .
Pressing the MODE switch, the accumulation count and accumulation value are
displayed.
Pressing the ZERO switch in the accumulation function ( is blinking), the current
function resets. (The count and accumulated value become zero.)
When the optional built-in printer is installed and the PRINT switch is pressed, the
accumulated data, date and data number are printed. The date is set at function table f16 .
Caution
The accumulation function can be used with the first weighing unit accumulated.
This function can display a maximum of six figures.
Parameter List and Word Definition
The "nearly-zero" is within ±4 digits from the zero point in the unit of kg.
The "digit", a unit of display, is equivalent to the minimum measurable mass.
The "zero point" is the fundamental starting point to weigh anything.
Function table Meaning and purpose
A
f8 0
Accumulation function not used.
A
f8 1
The scale accumulates the data, if the F switch is pressed, when
the display is a positive stable value without nearly-zero. The next
accumulation can be performed after the display is nearly-zero or a
negative value.
A
A
A
A
f8 2
The scale accumulates the data, if the F switch is pressed, when
the display is a stable value and without nearly-zero. The next
accumulation can be performed after the display is nearly-zero.
A
A
A
f8 3
When the display is a positive stable value, the scale accumulates
the data automatically. The next accumulation can be performed
after the display is nearly-zero or a negative value.
A
A
A