4.2 Hot Plug Support
Hot Plug insertion and removal are supported in the presence of a proper
connector and appropriate operating system (OS) support as described in the
SATA 2.6 and SATA 3 specification. This product supports Asynchronous Signal
Recovery and will issue an unsolicited COMINIT when first mated with a powered
connector to guarantee reliable detection by a host system without hardware
device detection.
5 Command Sets
The Element SSD complies with ATA-8. All mandatory and many optional
commands and features are supported. The tables below summarize the
supported ATA feature set and commands.
Table 5-1: ATA Feature Set
Support
Feature Set
ATA-8 REF
ATA Device
Element SSD
General feature set
4.2
M
YES
PACKET feature set
4.3
P
NO
48-Bit Address feature set
4.4
O
YES
Advanced Power Management (APM) feature set
4.5
O
NO
Automatic Acoustic Management (AAM) feature set
4.6
O
NO
CompactFlash Association (CFA) feature set
4.7
N
NO
Device Configuration Overlay (DCO) feature set
4.8
O
YES
Free-fall Control feature set
4.9
O
NO
General Purpose Logging (GPL) feature set
4.10
O
YES
Host Protected Area (HPA) feature set
4.11
O
YES
Long Logical Sector (LLS) feature set
4.12
O
NO
Long Physical Sector (LPS) feature set
4.13
O
NO
Media Card Pass Through Command feature set
4.14
N
NO
Native Command Queuing (NCQ) feature set 4.15 O YES
NV Cache feature set
4.16
O
NO
NV Cache Power Management feature set
4.17
O
NO
Power Management feature set
4.18
M
YES
Power-Up In Standby (PUIS) feature set
4.19
O
YES
Security feature set
4.20
O
YES
S.M.A.R.T. feature set
4.21
O
YES
Software Settings Preservation (SSP) feature set
4.22
O
YES