www.vikingtechnology.com
Table 2-8: Power Consumption at 3.3V
Client 480GB Enterprise — 400GB
6Gbps
3Gbps
6Gbps
3Gbps
RMS Power (W) RMS Power (W) RMS Power (W) RMS Power (W)
Write
5.11
4.57
5.71
4.84
Read
3.10
2.25
3.74
2.72
Idle 0.97 0.85 2.05 1.95
Notes:
1. Values based IOMeter 06: 100% Sequential, 256K Transfer, Q Depth: 32. Temperature: 25C
2.5 Environmental Conditions
2.5.1 Temperature and Altitude
Table 2-9: Temperature and Altitude Related Specifications
Condition
Operating
Shipping
Storage
Commercial
Temperature -
Ambient
0 to 70°c
(32 to 158° F)
-40 to 100°c
(-40 to 212° F)
-40 to 100°c
(-40 to 212° F)
Industrial
Temperature
2
-
Ambient
-40 to 85°c
(-40 to 185° F)
-40 to 100°c
(-40 to 212° F)
-40 to 100°c
(-40 to 212° F)
Humidity
(non-condensing)
10% to 80% 5% to 95% 5% to 95%
Max Temperature
Gradient
20°c/Hour
(36°F/Hour)
n/a n/a
Altitude
4
-304.8 to 24,384 m (-
1,000 to 80,000 ft)
-304.8 to 24,384 m
(-1,000 to 80,000 ft)
-304.8 to 24,384m
(-1,000 to 80,000 ft)
Storage Time
n/a
n/a
1 year
3
Notes:
1. RFU
2. Not available on VRFS1xGF series
3. Also refer to data retention specifications.
4. Max altitude specification for xxGAxx and xxGBxx part numbers is limited to 3048 m (10,000 ft)