A SERVICE OF

logo

EQQIC21W EQQIC25W
EQQIC21W INPUT APPLICATION
APPL
CONTAINS A DATE LATER THAN 1999-12-31 AND CANNOT BE
CONVERTED
Explanation: An application description in the input AD file is not valid 1999-12-31 or earlier, or it contains a run
cycle that is not valid 1999-12-31 or earlier, or it has been updated after 1999-12-31, so it cannot be converted for
fallback to a release that does not support dates later than 1999-12-31.
System action: The current input record is skipped. The migration program continues normal processing by reading
next record on the input file. Return code for the current CONVERT command will be 4 or higher.
System programmer response: Update the application description then resubmit the migration program.
EQQIC22I INPUT APPLICATION
APPL
HAS A VALID-TO DATE LATER THAN 1999-12-31. VALID-TO DATE SET
TO 1999-12-31
Explanation: An application description in the input AD file has a valid-to date later than 1999-12-31 or a run cycle
with an out-of-effect date later than 1999-12-31 when converting for fallback to a release that does not support dates
after 1999-12-31.
System action: The current input record is converted. Valid-to date, or out-of-effect date, is set to 1999-12-31.
The migration program continues normal processing by reading next record on the input file.
System programmer response: None.
EQQIC23W INPUT PERIOD
PER
CONTAINS A DATE LATER THAN 1999-12-31 AND CANNOT BE CONVERTED
Explanation: A period description in the input WS file has an interval origin date or interval end date later than
1999-12-31, or the description has been updated after 1999-12-31, so it cannot be converted for fallback to a release
that does not support dates later than 1999-12-31.
System action: The current input record is skipped. The migration program continues normal processing by reading
next record on the input file. Return code for the current CONVERT command will be 4 or higher.
System programmer response: Update or delete the period description record and resubmit the migration program.
EQQIC24W INPUT WORKSTATION DESCRIPTION
WS
HAS A DATE LATER THAN 1999-12-31 AND CANNOT BE
CONVERTED
Explanation: A workstation description in the input WS file has a specific date later than 1999-12-31, or the
description has been updated after 1999-12-31, so it cannot be converted for fallback to a release that does not
support dates later than 1999-12-31.
System action: The current input record is skipped. The migration program continues normal processing by reading
next record on the input file. Return code for the current CONVERT command will be 4 or higher.
System programmer response: Update or delete the workstation description and resubmit the migration program.
EQQIC25W INPUT CALENDAR
CAL
CONTAINS A DATE LATER THAN 1999-12-31 AND CANNOT BE
CONVERTED
Explanation: A calendar description in the input WS file has a specific date later than 1999-12-31, or it has been
updated after 1999-12-31, so it cannot be converted for fallback to a release that does not support dates later than
1999-12-31.
System action: The current input record is skipped. The migration program continues normal processing by reading
next record on the input file. Return code for the current CONVERT command will be 4 or higher.
System programmer response: Update or delete the calendar description and resubmit the migration program.
Chapter 12. EQQICnn Messages 125