A SERVICE OF

logo

FOX 500 DA6 • Remote Control
Remote Control, cont’d
3-14
FOX 500 DA6 • Remote Control
3-15
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Information requests
Information request I
1Link
X1^
•2Link
X1^
•RGB
X1^
•Aud
X1^
X1&
X1*]
The unit responds with the current status (signal
detected) of optical link 1, optical link 2, the video input,
the audio input, the fiber optic mode (singlemode or
multimode), and the device type (Tx or Rx).
N
The master receiver monitors the fiber 1 cable. If the PC is connected to the DA and fiber cable 2 is not installed bewtween the DA and the
master receiver, for the information request (I) and Status commands (S) below, the DA reports 1Link0 regardless of the status of the fiber 1
cable.
Show firmware version Q
X1%]
Example:
Q
1.23
]
The factory-installed FOX 500 controller firmware version
is 1.23 (sample value only).
Request part number N
60-nnn-nn
]
See appendix A for part numbers.
Show link 1 status 1S
X1^]
0 = light link not received at receiver, 1 = light received.
Show link 2 status 2S
X1^]
0 = light link not received at DA, 1 = light received.
Show input video status 3S
X1^]
0 = video is not input to the DA, 1 = video is input.
Show input audio status 4S
X1^]
0 = audio is not input to the DA, 1 = audio is input.
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Resets
Reset audio gain and
attenuation
E
ZA
}
Zpa
]
Reset all audio settings to default (0 dB gain and
consumer [-10 dB] level).
Reset presets
E
ZG
}
Zpg
]
Reset (erase) all memory presets.
System reset
E
ZXXX
}
Zpx
]
Reset all settings to the factory defaults.
Command/response table for SIS commands (continued)