RayTek 54301 Thermometer User Manual


 
Operation
6.4.5AdvancedValleyHold
Thisfunctionworks similar tothe advancedpeak holdfunction,
exceptitwillsearchthesignalforalocalminimum.
6.4.6AdvancedPeakHoldwithAveraging
Theoutputsignaldeliveredbytheadvancedpeakholdfunctions
tends to jump up and down. This is due to the
fact, that only
maximumpointsoftheotherwisehomogenoustracewillbeshown.
Theusermaycombinethefunctionalityofthepeakholdfunction
with the averaging function by choosing an average time, thus,
smoothingtheoutputsignalforconvenienttracing.
output temperature
object temperature
without averaging
Temp
Time
Figure29:AdvancedPeakHoldwithAveraging
Theadvancedpeakholdfunctionwithaveragingisonlyadjustable
bymeansoftheDataTempMultiDropSoftware.
6.4.7AdvancedValleyHoldwithAveraging
Thisfunctionworkssimilartotheadvancedpeakholdfunctionwith
averaging,exceptitwillsearchthesignalfora
localminimum.
MID 43