Pride Mobility 1122 Wheelchair User Manual


 
Jazzy 1122 www.pridemobility.com 51
IX. CARE AND MAINTENANCE
9. Connect the wire labeled BAT (+) to the other battery’s positive (red) terminal. Connect the wire labeled BAT
(-) to the negative (black) terminal. Install the battery in the front of your power chair’s battery tray with the
battery’s terminals facing inward, toward the center of the power chair. Plug the wiring harness into a quick
disconnect.
WARNING! Make sure you tighten the fasteners so that the connections are secure.
10. Replace the foot frame using the detent pin to secure.
When to See Your Authorized Pride Provider for Service
The following symptoms could indicate a serious problem with your power chair. If necessary, contact your autho-
rized Pride Provider. When calling, have the model number, serial number, nature of the problem, and the trouble code
if available.
! Motor noise
! Frayed harnesses
! Cracked or broken connectors
! Uneven wear on any of the tires
! Jerky motion
! Pulling to one side
! Bent or broken wheel assemblies
! Does not power up
! Powers up, but does not move
Corrective Maintenance
If the battery condition meter does not light up when you turn on the power:
! Check the harness connections. Make sure they are tight.
! Check the circuit breaker. Reset it if necessary.
! Check the battery connections.
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are
available at automotive parts stores. Disconnect both batteries before load testing and follow the directions that
come with the load tester. If either one of the batteries fails the load test, replace both of them. If your power chair
still does not power up, contact your authorized Pride Provider.