PAGE 84 C-30HD PARTS & OPERATION MANUAL REV. #4 (03/06/01)
Important
Adjust linkage as follows:
1. Energize the solenoid which will bottom the solenoid
plunger.
2. Screw eyebolt into bell crank swivel until all slack is
removed from chain, and idle set screw is full idle
position. Note: Remove gas line to carburetor to permit
easy installation of eye bolt in bell crank.
3. Tighten jam-nut to prevent eye bolt from unscrewing.
C-30HD SERVICE INFORMATION LINKAGE ADJUSTMENT OLD STYLE SOLENOID
SIDE VIEW FROM STARTER SIDE OF ENGINE
EM26315
EM26730
P/N EM26730
EM14706
EM16701
EM14708
EM14707
(OBSOLETE)