Maxon Telecom WL7-VERS. C Mobility Aid User Manual


 
PATENTS PENDING
39
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
CHECKING HYDRAULIC FLUID LEVEL
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic sys-
tem. Before opening the hydraulic uid reservoir ller cap, drain plug and
hydraulic lines, wipe off contaminants that can get in the openings. Also,
protect the openings from accidental contamination.
2. If needed, add uid to the reservoir
as follows. Unbolt the pump cover as
shown in FIG. 39-2.
1. Check the hydraulic uid level in reservoir as
follows. With Lift in STOWED position, uid
level should be as shown in FIG. 39-1.
UNBOLTING/BOLTING PUMP COVER
(LH PUMP SHOWN)
FIG. 39-2
INSPECTION
SLOT
RESERVOIR
HYDRAULIC FLUID LEVEL
(LH PUMP SHOWN)
FIG. 39-1
2”
PUMP
COVER
SCREWS
PUMP COVER
!