Maxon Telecom WL7-VERS. C Mobility Aid User Manual


 
PATENTS PENDING
33
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
NOTE: If there is a grounding
point on the frame, use it
to connect ground cable.
Skip step 8.
8. Extend the ground cable to reach
vehicle frame (FIG. 33-2). Con-
nect to an existing grounding point
if available. If necessary, drill a
13/32” (0.406”) hole in vehicle
frame for bolting the ground cable
terminal lug (FIG. 33-2).
VEHICLE
FRAME
3/8” LOCK
WASHER
GROUND
CABLE
3/8”-16 X 1” LG.
CAP SCREW
3/8”-16
HEX NUT
BOLTING GROUND CABLE
TO VEHICLE FRAME
FIG. 33-2
7. Uncoil the ground cable from the bottom of
the pump cover. Route the ground cable
on the Lift through grommet in vehicle oor
(FIG. 33-1A & 33-1B).
GROUND CABLE ROUTED FROM LIFT
FIG. 33-1A
GROUND
CABLE
TERMINAL LUG
9. Bolt the ground cable terminal lug
to vehicle frame as shown in FIG.
33-2.
GROMMET
NOTE: Clean the ground cable
connection point on the
frame down to bare metal.
NOTE: Apply dielectric grease to
all electrical connections.
BARE
METAL