Hague Quality Water Intl 63MAQ Home Dialysis Equipment User Manual


 
Troubleshooting
Problem
Cause
Solution
Salty water
Plugged injector.
Low water pressure.
Drain line or flow control is restricted.
Brine line restricted or crimped.
Excessive amount of water in
brine
cabinet.
Insufficient
rinse time.
Intermittent pressure drop from feed
source.
Clean injector screen, nozzle and
throat (See
Fig. 6)
Maintain minimum pressure of 30
psi
(See
Engineering
Specs.)
Remove restriction.
Remove restriction, replace
if
crimped.
Verify correct water level relative
to
salt setting.
Check brine line and fit-
tings for
loose
connections (See
Brine Cabinet Data, page 36.)
Check mode setting chart (pg. 14-
15) for proper brine rinse time.
Adjust
ti
me, if
necessary.
Install check
valve on the inlet water
li
ne to the appliance.
(Check
local
plumbing
codes first.)
NOTES:
19