Emerson Process Management I-0320 Oxygen Equipment User Manual


 
(I-0320--.doc/5)
5
MULTIPORT SIZE
AND RATING
NPS 2"
ANSI 600
NPS 3"
ANSI 600
NPS 3"
ANSI 900/1500
NPS 4"
ANSI 600
NPS 4"
ANSI 900
TEST OUTLETC
V
67 151 100 270 218
GROUP OUTLET C
V
262 594 429 1040 830
SHELL
HYDROSTATIC
TEST PRESSURE
PSIG (KPa)
2200-2220
(13780-15300)
2160
(14900)
5560
(38310)
2220
(15300)
3330
(22950)
MAXIMUM DYNAMIC DIFFERENTIAL
PSID @ 40ΕC
STATIC STATIONARY DIFFERENTIAL
PSID @ 40ΕC
MULITPORT SIZE
AND RATING
TEST-GROUP
GROUP-TEST
TEST-GROUP
GROUP-TEST
NPS 2X4
ANSI 600
600 550 1200 900
NPS 3X6
ANSI 60
500 450 1000 700
NPS 3X6
ANSI 900/1500
500 450 1000 700
NPS 4X8
ANSI 600
400 350 800 600
NPS 4X10
ANSI 900
400 350 800 600
Note: In Emergency situations only, the Multiport Flow Selector seal can maintain STATIC
STATIONARY DIFFERENTIAL pressure rating per specifications above. However, do not operate
the motor operator at greater than the MAXIMUM DYNAMIC DIFFERENTIAL pressure rating
because damage may occur to the motor operator.
IIB
ACTUATOR SPECIFICATIONS:
MULTIPORT SIZE
AND RATING
NPS 2"
ANSI 600
NPS 3"
ANSI 600
NPS 3"
ANSI 900/1500
NPS 4"
ANSI 600
NPS 4"
ANSI 900
PLUG POSITION
TOLERANCE
+/- 2Ε +/- 2Ε +/- 2Ε +/- 2Ε +/- 2Ε
BREAKAWAY
TORQUE @ MAX
DIFFERENTIAL
100-125 FT-LBS 100-170 FT-LBS 150-200 FT-LBS 150-210 FT-LBS 150-210 FT-LBS
ACTUATOR SPEED 1.4 RPM 1.4 RPM 1.4 RPM 1.4 RPM 1.4 RPM
ACTUATOR
WEIGHT
50 LBS 130 LBS 130 LBS 130 LBS 150 LBS
PLUG POSITION
ACCURACY
+/- 1Ε +/- 1Ε
+/- 1Ε
+/- 1Ε
+/- 1Ε