6. Cut wires close to old fan (10).
7. Splice wires to new fan (10).
8. Mount new fan (10) to fan mounting
bracket (7) using screws (8) and wash-
ers (9).
9. Mount fan assembly (7, 10) to mount-
ing plate (15) using screws (5) and
washers (6).
10. Reinstall protective cover (4) using
screws (2) and washers (3).
11. Close door cover (1) and secure with
screws (5, Figure E-7).
1. Cover Door
2. Screw
3. Washer
4. Protective Cover
5. Screw
6. Washer
7. Fan Mounting Bracket
8. Washer
9. Screw
10. Fan
11. Screw
12. Washer
13. Screw
14. Washer
15. Mounting Plate
16. Screw
17. Washer
18. Thermoswitch Mounting Plate
19. Thermoswitch
20. Heater Mounting Plate
21. Heater
22. Electrical Plug
23. Enclosure
24. Nylon Washer