6 — MONITOR MENU
MONITOR MENU
Through its Monitor menu, the 1311 programmer provides access to real-time
data during chair operation. The Monitor menu has six submenus, which follow
the Active Config parameter at the top of the menu:
MONITOR MENU
—Active Config
Handcontrol
—Seat
—Lights
—Motor Controller
—Motors & Brakes
—Battery
MONITOR MENU
DISPLAY
ITEM RANGE DESCRIPTION
Active Config 1–4 Configuration that is currently selected.
HANDCONTROLS • •
Handcontrol SW Ver. 0 – 255 Version number of the handcontrol software.
Drive Command -100 – +100 % Requested normalized (to 100%) Y-axis
throttle request incorporating the deadbands.
Turn Command -100 – +100 % Requested normalized (to 100%) X-axis
throttle request incorporating the deadbands.
Speed Mode 1 – 9 Speed Mode setting.
Speed Command 0 – 100 % Speed Limit value in effect.
Horn Button On/Off Status of the Horn button.
Mode Button On/Off Status of the Mode button.
Aux 1 Button On/Off Status of the Aux 1 button (
).
Aux 2 Button On/Off Status of the Aux 2 button (
).
Left Turn Button On/Off Status of the Left Turn button.
Right Turn Button On/Off Status of the Right Turn button.
Hazards Button On/Off Status of the Hazards button.
Running Lights Button On/Off Status of the Running Lights button.
Handcontrol Inhibit On/Off Status of the Handcontrol Inhibit input.
SEAT • •
Actuator 1 Voltage -37.5 – +37.5 V Voltage applied to Actuator Motor 1.
Actuator 2 Voltage -37.5 – +37.5 V Voltage applied to Actuator Motor 2.
Actuator Current -12.0 – +12.0 A Current through the actuator motors.