Curtis 40 Wheelchair User Manual


 
29
Curtis enAble
®
40-Series Manual, Rev. B
5 — PROGRAMMABLE PARAMETERS: Lights and Current Limits Parameters
LIGHTS MENU
PARAMETER RANGE DESCRIPTION
Running Lights On/Off Set to On if the vehicle has running rights.
Running Light Volts 12–24 V Defines the voltage for the running lights. Bulbs will be held at a
constant brightness.
Min Light Current
*
0–26.5 A Defines the minimum allowed driver current for the running lights;
below this current, a fault will be declared.
Indicators On/Off Set to On if the vehicle has indicator lights.
Indicator Volts 12–24 V Defines the voltage for the indicator lights. Bulbs will be held at a
constant brightness.
Min Indicator Current
*
0–26.5 A Defines the minimum allowed driver current for the indicator lights;
below this current, a fault will be declared.
Indicator Timeout 0–30 sec Sets the maximum amount of time an indicator light will flash before
auto-shutdown. Setting this parameter to 0 disables this function.
*
To set these minimum driver currents accurately, base your calculations
on the monitored values for Running Light Current and Indicator Current
as displayed in the programmer’s Monitor menu.
CURRENT LIMITS MENU
PARAMETER RANGE DESCRIPTION
Peak Current Limit 25–75 A
*
Provides a boost. Sets the motor current limit that will be allowed for
the peak current time.
Peak Current Time 0–60 sec Sets the maximum time that the peak current is allowed.
Drive Current Limit 25–60 A
*
Sets the motor current limit during normal driving.
Brake Current Limit 25–60 A
*
Sets the motor current limit during regen braking.
*
The current limit range maxes out at 50 A for 50-amp controllers.