Chief Manufacturing CM2C40 Mobility Aid User Manual


 
CM2C40 Installation Instructions
18
IR-SE15 Programming
IR-SE15 Control Features:
Carrier Frequency:38KHz
Protocol:NEC - Full Repeat
System Code(s):6E (Default) - Multiple Codes
Selected via Key-Press (see below)
To Change System Code:
1. Press and Release Key 3 + 7 (Enter Setup Mode)
2. Press and Release Key 8
3. Press and Release Key 10
4. Press and Release Key 12 - LED Blinks Twice <Quick>
5. Select System Code - See Table Below
6. Press and Release Key 2 - LED Blinks 4 times <Quick>
(Exit Setup Mode)
Figure 30
Table 1-2: IR-SE15 Control Codes
Key Number Key Name Hex Code
1 HOME 02
2 SAVE 1A
3 UP 07
4 LEFT 09
5 STOP 0A
6 RIGHT 0B
7 DOWN 0D
8 PRESET 1 12
10 PRESET 2 13
12 PRESET 3 14
Table 1-3:
System
Code
Press +
Release
6E (Default) 8
E1 8,8,8,8
E2 10
E3 10,8
E4 10,8,8
E5 10,8,8,8
E6 10,8,8,8,8
E7 12
1
2
3
7
5 6
8
10
12
4