Page 41
Maintenance and Lubrication
All listed inspection, lubrication and maintenance
procedures should be repeated at “750 cycle”
intervals following the scheduled “4500 Cycles”
maintenance. These intervals are a general
guideline for scheduling maintenance procedures
and will vary according to lift use and conditions.
Lifts exposed to severe conditions (weather,
environment, contamination, heavy usage, etc.)
may require inspection and maintenance proce-
dures to be performed more often than specified.
Maintenance Indicator: The Lift Ready green
LED, mounted on the hand-held pendant storage
bracket, will change color to yellow after every
750 cycles. The yellow LED will not affect the
functions of the lift, but is a reminder to complete
necessary maintenance and lubrication proce-
dures. Once the lift has been serviced, press the
CYCLE button (located below LCD display on the
control board) until the Lift Ready LED changes
back to green. The CYCLE button also clears
the lift cycle count (since last service) but not the
lifetime cycle count.
Discontinue lift use immediately if maintenance
and lubrication procedures are not properly per-
formed, or if there is any sign of wear, damage
or improper operation. Contact your sales repre-
sentative or call The Braun Corporation at 1-800-
THE LIFT
®
. One of our national Product Support
representatives will direct you to an authorized
service technician who will inspect your lift.
Specified (recommended) Available Braun
Lubricant Type Lubricant Amount Part No.
See the Maintenance/Lubrication Schedule for recommended applications per number of cycles.
LO - Light Oil
DE - Door-Ease
Synthetic Grease Mobiltemp SHC32 12.5 oz.
(Multipurpose) Tube
SG - Synthetic Grease
15807
15806
28598
Light Penetrating Oil LPS2, General Purpose 11 oz.
(30 weight or equivalent) Penetrating Oil Aerosol Can
Stainless Stick Door-Ease 1.68 oz.
Style (tube) Stick (tube)