Agilent Technologies 6000 Series Respiratory Product User Manual


 
Software applications
I
2
C/SPI serial trigger and decode
(N5423A or Option LSS on new scope
purchases)
This application displays real-time time-
aligned decode of I
2
C and SPI serial buses.
Hardware-accelerated decode means the
scope stays responsive and fast.
This application requires a 4-channel DSO or
4-channel MSO and can use any combinatio
of the scope or logic acquisition channels.
For more information:
www.agilent.com/fi nd/I
2
C-SPI
CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases)
Trigger on and decode serially transmitted data based on CAN and LIN protocols. This applica-
tion not only provides triggering on complex serial signals, but it also provides unique hardware-
accelerated capabilities. Hardware-accelerated triggering and decode means the scope stays
responsive and fast.
This application requires a 4-channel DSO or 4-channel MSO and can use any combination of
scope or logic acquisition channels.
For more information: www.agilent.com/fi nd/CAN-LIN
FlexRay triggering and decode (N5432A or Option FRS on new scope purchases)
FlexRay protocol is based on time-triggered and deterministic architecture. Agilent’s FlexRay
solution for the 6000 Series mixed signal oscilloscopes offers a robust set of FlexRay frame,
slot, and error triggering, including the ability to trigger on specifi c FlexRay communications
qualifi ed on base-cycle and cycle-repetition. This solution combines an Agilent 6000 Series
mixed signal oscilloscope (MSO) with an Agilent VPT 1000 vehicle protocol tester for FlexRay
protocol analyzer.
This application requires a 4-channel MSO.
For more information: www.agilent.com/fi nd/fl exray
RS-232/UART serial decode and trigger (N5457A or Option 232 on new scope purchases)
Does your design include RS-232 or another type of UART? This application eliminates the need
to manually decode bus traffi c. Using data captured on the scope or logic channels, the applica-
tion lets you easily view the information sent over a RS-232 or other UART serial bus.
Display real-time time-aligned decode of transmit and receive lines. The application also enables
triggering on RS-232/UART conditions.
This application requires a 4-channel DSO or 4-channel MSO and can use any combination of
the scope or logic acquisition channels.
For more information:
www.agilent.com/fi nd/RS-232
View on-screen serial decode of an I
2
C packet.
Trigger on and decode RS-232/UART
transmission.
Trigger on and decode CAN serial packets.
See mixed signal measurements in a
FlexRay system using an MSO.
8