Agilent offers a complete family of innovative passive and active probes for the
InfiniiVision 6000 Series scopes to get your job done easily and accurately. Choosing
the correct probe for your application will help to ensure you are acquiring the signals
you expect. Below is a general guide on how to choose the type of probe. For the
most up-to-date information about Agilent’s accessories, please visit our Web site
at www.agilent.com/find/scope_probes.
Probe type Key characteristics DSO601xA, MSO601xA
DSO603xA, MSO603xA
DSO605xA, MSO605xA
DSO610xA, MSO610xA
Passive probes: most common type of probe, rugged and economical with bandwidth generally lower than 600 MHz
10070C
10073C
10074C
1:1 20 MHz with probe ID
10:1 500 MHz with probe ID
10:1 150 MHz with probe ID
Recommended*
Compatible*
Included*
Recommended
Included
Compatible
High voltage passive probe: view up to 30 kVDC + peak AC voltage referenced to earth ground
10076A
N2771A
100:1, 4 kV, 250 MHz probe with ID
1000:1, 30 kV, 50 MHz probe
Recommended
Recommended
Recommended
Recommended
Single-ended active probes: contains small, active amplifier and enables the probe input capacitance to be very low resulting in high
input impedance on high frequencies. Least intrusive of all probes.
1156A
1144A
1145A
1.5 GHz AutoProbe interface
800 MHz (requires 1142A – power supply)
750 MHz 2-ch (requires 1142A – power supply)
Incompatible*
Incompatible
Incompatible
Recommended
Recommended
Recommended
Active differential probes: use to look at signals that are referenced to each others instead of earth ground and to look at small signals in
the presence of large DC offsets or other common mode signals such as power line noise.
1130A
N2772A
1141A
1.5 GHz InfiniiMax amplifier with AutoProbe interface (requires one
or more InfiniiMax probe head – E2675A, E2668A, E2669A)
20 MHz, 1.2 kVDC + peak AC max (requires N2773A power supply)
200 MHz, 200 VDC + peak AC max (requires 1142A power supply)
Incompatible
Recommended
Compatible
Recommended
Recommended
Recommended
Current probes: sense the AC or DC current flowing through a conductor and convert it to a voltage that can be viewed and measured on
an oscilloscope. Compatible with 1 MΩ scope input.
1146A
1147A
N2780A
N2781A
N2782A
N2783A
100 kHz, 100 A, AC/DC
50 MHz, 30 A, AC/DC with AutoProbe interface
2 MHz, 500 A, AC/DC (use with N2779A power supply)
10 MHz, 150 A, AC/DC (use with N2779A power supply)
50 MHz, 30 A, AC/DC (use with N2779A power supply)
100 MHz, 30 A, AC/DC (use with N2779A power supply)
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
MSO probes: offer the best performance and access to the industry’s broad range of logic analyzer probing accessories
01650-61607**
54620-68701
40-pin, 16-channel logic probe
Logic probe with 2x8 flying leads (includes 20 IC clips and five
ground leads)
Recommended with
MSO6000 models
Recommended and
included with MSO6000
models
Recommended with
MSO6000 models
Recommended and
included with MSO6000
models
* Recommended is a suggestion from Agilent scope and probing experts that this probe works well with this scope.
Compatible indicates that the probe and scope will work together but that there are other choices that will work better.
Included means that this probe ships with this scope.
Incompatible is a warning that the probe will not work with the indicated scope.
** With the addition of 40-pin logic cable, the Agilent MSO accepts numerous logic analyzer accessories such as Mictor, Samtec, flying leads or soft touch connectorless probe.
For more comprehensive information, refer to the Agilent InfiniiVision Series Oscilloscopes Probes and Accessories Data Sheet and
Selection Guide (Agilent publication numbers 5968-8153EN/ENUS and 5989-6162EN).
11