The ACD-10 is expandable from 6 to 10 stations with the optional ACD-10-EB. In addition to gaining 4 more stations,
there is also the “Transfer Only” station feature available on stations 16, 17, 18 and/or 19. Follow the instructions below
to install the expansion board.
A. ACD-10-EB Expansion Board
3. Programming
Programming of the ACD-10 remains unchanged with the addition of the ACD-
10-EB except for the “Transfer Only” feature shunts available on the ACD-10-
EB board. Remove the shunt to activate the “Transfer Only” feature for that
associated station.
J2
J11
J1
1
49
1
9
ACD-10-EB Board
Internal View of the ACD-10
(4) 4x40 ¼"
Screws
(included)
2. Station Activation
To Activate Stations 16 - 19...
Step 1. Come off-hook on the station you wish to activate.
Step 2. Dial “682” and hang up.
Step 3. Repeat steps 1 and 2 for each station you wish to activate.
1. Installation
Important: Electronics compo-
nents are sensitive to static elec-
tricity. Personnel and the work
area should be grounded before
handling.
Step 1. Power down the ACD-10.
Step 2. Remove the ACD-10 cover using the supplied 3/32” hex key.
Step 3. Snap the ACD-10-EB into place as shown below.
Step 4. Secure the ACD-10-EB board with the supplied 4x40¼” screws.
Step 5. Carefully plug the two ribbon cable connectors into the J2 and J11 pins as shown below.
Step 6. Remove shunts to activate “Transfer Only” station feature if needed.
Step 7. Replace the cover on the ACD-10 and power the unit on.