Toshiba LF654 Oxygen Equipment User Manual


 
TIC-LF654L
7
ASME B 16.5 class 150 dimensions:
Meter size
(inch)
L1
(inch)
L2
(inch)
L3
(inch)
No. of
bolts
Weight
(lbs)
1/2 5.51 6.77 8.54
4 approx. 9.0
1 6.30 7.01 9.13
4 approx. 14.0
1-1/4 7.87 7.32 9.65
4 approx. 18.0
1-1/2 6.69 7.36 9.88
4 approx. 18.0
2 7.09 7.80 10.79
4 approx. 27.0
2-1/2 7.87 7.99 11.50
4 approx. 36.0
3 9.06 8.39 12.13
4 approx. 42.0
4 9.45 8.98 13.50
8 approx. 62.0
5 9.84 9.41 14.41
8 approx. 71.0
6 10.24 10.04 15.55
8 approx. 91.0
8 11.81 10.94 17.72
8 approx. 137.0
10 13.78 11.85 19.84
12 approx. 205.0
12 15.75 13.35 22.83
12 approx. 313.0
14 17.72 13.58 24.09
12 approx. 401.0
16 19.69 14.49 25.91
16 approx. 507.0
18 21.65 15.39 27.91
16 approx. 614.0
EN1092-1 PN 16 dimensions:
Meter size
(mm)
L1
(mm)
(L2)
(mm)
L3
(mm)
No. of
bolts
Weight
(kg)
15 140 170 218 4 approx. 4.0
25 160 176 239 4 approx. 5.5
32 200 184 252 4 approx. 8.0
40 170 185 255 4 approx. 8.5
50 180 199 277 4 approx. 12.5
65 200 204 292 4 approx. 14.5
80 230 222 314 8 approx. 19.5
100 240 229 334 8 approx. 24.5
125 250 240 366 8 approx. 29.0
150 260 252 392 8 approx. 35.5
200 300 277 442 12 approx. 52.0
250 350 302 502 12 approx. 76.0
300 400 332 555 12 approx. 115.0
350 450 341 586 16 approx. 154.5
400 500 364 644 16 approx. 200.5
450 550 387 697 20 approx. 247.5
JIS B 2220 10K dimensions:
Meter size
(mm)
L1
(mm)
(L2)
(mm)
L3
(mm)
No. of
bolts
Weight
(kg)
15 140 170 218 4 approx. 4.0
25 160 176 239 4 approx. 6.5
32 200 184 252 4 approx. 8.5
40 170 185 255 4 approx. 8.0
50 180 199 277 4 approx. 11.5
65 200 204 292 4 approx. 14.5
80 230 222 314 8 approx. 16.0
100 240 229 334 8 approx. 21.5
125 250 240 366 8 approx. 28.0
150 260 252 392 8 approx. 35.0
200 300 277 442 12 approx. 46.5
250 350 302 502 12 approx. 72.0
300 400 332 555 16 approx. 100.0
350 450 341 586 16 approx. 125.0
400 500 364 644 16 approx. 173.0
450 550 387 697 20 approx. 215.0
Figure 5. Separate type detectors LF654
Meter sizes 1/2" (15) to 18"
(450mm) for Toshiba lay length
Note1: Eye bolts are provided at the top for flowmeters sized 8”(200mm) or above, and further, a
roll-prevention base is provided for flowmeters 10”(250mm) or larger.
Note2: Cable glands are not provided for LF654 of cFMus approved type. Refer to the cable connection
d