Toshiba LF654 Oxygen Equipment User Manual


 
TIC-LF654L
14
Table 4. Specification Code (Flange type detector LF654 Series)
Model Specification Code
Description
Detector category
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Gr.-A Gr.-B
L F 6 5 Flange type electromagnetic flowmeter detector
4
Usage
cFMus Class 1 Division 2 Hazardous Location
Meter size
D ½"(15mm)
E 1"(25mm)
S 1¼"(32mm)
F 1½"(40mm)
G 2"(50mm)
W 2½"(65mm)
H 3"(80mm)
J 4"(100mm)
U 5(125mm)
K
6"(150mm)
L 8"(200mm)
M 10"(250mm)
N 12"(300mm)
P 14"(350m
m
)
Q 16"(400mm)
R 18"(450m
m
)
Mounting Style(Note1)(Note6)
L Detector/Converter combined type
M Detector/Converter separate type
Connection flange standard, Overall length
C ASME B 16.5 class 150, ISO length
D ASME B 16.5 class 300, ISO length
G EN 1092-1 PN 10, ISO length
H EN 1092-1 PN 16, ISO length
1 ASME B 16.5 class 150, Toshiba length
2 ASME B 16.5 class 300, Toshiba length
5 EN 1092-1 PN 10, Toshiba length
6 EN 1092-1 PN 16, Toshiba length
Z Othe
r
(Note 2)
Electrode Material (Note 3)(Note 4)
B 316L stainless steel (Standard for PU, HR lining)
C Ti (titanium)
D Pt-Ir (platinum/iridium)
E Ta (tantalum)
F Hastelloy C (Equivalent) (Standard for PFA lining)
Lining Materials (Note 3)
C PFA
N PU(Polyurethane) with NSF certified
E HR(Hard Rubber) with NSF certifie
d
Grounding Ring Material (Note 3)(Note 4)
C 316 stainless steel
D 316L stainless steel
E Ti (titanium)
F Ta (tantalum)
G Pt-Ir (platinum/iridium)
H Hastelloy C (Equivalent)
Flow and calibration velocity range
A 1.0 to 32.8 ft/s (standard range calibration)
(Note 5)
Excitation and Signal Cables
A not provide
d
Coating
F PU coating pearl-gray colore
d
C
b
lack tar epoxy resin
Size code explanation: : Object : Standard : Option
: Not available
Note1: In case of LF654 with cFMus approval, Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter.
Note2: Connection flange standard EN 1092-1 PN10, EN 1092-1 PN 16,JIS B 2220 10K and JIS B 2220 20K are optional for both ISO length and Toshiba
length.
Note3: Consult Toshiba before ordering when choosing materials at the wetting parts.
Note4: In case of PU and HR lining with NSF approval, only 316/316L stainless steel are available, and Hastelloy C & Ti are undergoing testing.
Note5: User specified range upon request, additional charges apply.
Note6: Potting kit is available for submersible option when selecting Detector/Converter separate type with PU or HR lining. Please consult Toshiba for
details.