Sterling 822.00292.00 Hair Dryer User Manual


 
Large Dehumidifying Dryers Controls 29
Identifying Temperature Controller Keys
Indicator Name Description
Mode Key Press the Mode key to shift the display to the next
set of parameters. The menu screen displays.
Down Key Press the Down arrow key to lower the process air
set point temperature. During setup, it lets you
decrease the value of the parameter displayed on
the set point LED readout.
Up Key Press the Up arrow key to raise the process air set
point temperature. During setup, it lets you
increase the value of the parameter displayed on
the set point LED readout.
Setting the Process Air Temperature
When setting the process air temperature, consult with the resin manufacture for the
recommended drying temperature.
To change the process air temperature set point with the dryer running:
Press to raise the set point to the temperature you want.
Press to lower the set point to the temperature you want.
Restoring the Process Air Temperature Controller (E5CN) to Factory Settings
If the preset parameters on the controller have been tampered with and it no longer properly
controls temperature and displays dew point, you can restore the controllers to the factory
setup. Call the Service Department for detailed instructions.
E5CN Operating Parameters
The E5CN controller has several mode selections. Within each mode are numerous
parameters that can be set.
The factory has set the security level to protect the critical parameters from being accidentally
changed. Below is an explanation of the operating modes you will have access to and on the
following page are the manufacturers’ default settings.