42 www.pridemobility.com Jazzy 1101/1121/Rev E/Jun03
VIII. OPERATION
Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power
interface between the power module, the lights, and/or the power seat actuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main
power if the joystick is not moved in any direction for approximately five minutes. The battery condition meter lights on the
keypad indicate sleep mode by blinking once every five seconds. To restore power and continue, push the on/off key
twice.
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power
module, and remote. In the event that any of them become excessively hot (above 122° F), motor voltage is reduced. For
every degree above 122° F, the voltage is reduced by 5 volts. This reduces your power chairs speed and allows the
electrical components to cool down. When the temperature returns to a safe level, your power chair resumes its normal
speed.
Remote Plus Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems
with your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that
are flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light
is flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing meter. When you get a trouble code, contact your authorized Pride Provider.
FLASHING LIGHTS DIAGNOSIS SOLUTION
10 High Battery Voltage Check batteries.
9 Solenoid Brake Fault Check motor/brake wiring.
8 Possible Controller Fault See authorized Pride Provider.
7 Possible Joystick Fault See authorized Pride Provider.
6 Inhibit Active Unplug charger. Check connections.
5 Right Motor Wiring Fault Check right motor wiring.
4 Right Motor Disconnected Check right motor wiring.
3 Left Motor Wiring Fault Check left motor wiring.
2 Left Motor Disconnected Check left motor wiring.
1 Low Battery Voltage Check batteries/battery wiring.