Pride Mobility 1100 Mobility Aid User Manual


 
52 www.pridemobility.com Jazzy 1100/RevJ/Feb03
WHEN TO SEE YOUR JAZZY PROVIDER FOR SERVICE
The following symptoms could indicate a serious problem with your Jazzy 1100. If necessary, contact an
authorized Pride provider. When calling, have the model number, serial number, nature of the problem, and
the trouble code if available.
n Motor noise
n Frayed harnesses
n Cracked or broken connectors
n Uneven wear on any of the tires
n Jerky motion
CORRECTIVE MAINTENANCE
If the battery indicator gauge does not light up when you turn on the power:
n Check the harness connections. Make sure they are tight.
n Check the circuit breaker. Reset it if necessary.
n Check the battery connections.
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers
are available at automotive parts stores. Disconnect both batteries before load testing and follow the direc-
tions that come with the load tester. If either one of the batteries fails the load test, replace both of them. If
your Jazzy 1100 still does not power up, contact your local Pride provider.
X. CARE AND MAINTENANCE
n Pulling to one side
n Bent or broken wheel assemblies
n Does not power up
n Powers up, but does not move