Power
The supply voltage and power requirements are shown in the table below. The
power will vary greatly depending on the number of pixels lit and depending
on the chosen luminance level (see graph below.) Power levels will vary up to
+/-15 % from display to display due to brightness variation.
DC Input Voltage and Power Requirements
Parameter Minimum Typical Maximum Abs Max
Display supply voltage, V
H
8 V 12 V 18V
Supply current at +12 V 0.45 A 0.95 A 1.09 A
Power consumption @ maximum
luminance (LUM0=LUM1=0)
5.4 W 11.4 W 13.1 W
Power consumption @ minimum
luminance (LUM0=0, LUM1 =1)
3.5W 6.9 W
Quiescent power consumption
(SHUTDOWN = 1)
0.5 W
Note: 1) Maximum power: 90% of pixels lit (yellow) per row
2) Abs Max power: 90% of pixels lit (yellow) per row, worst case display sample
2) Typical power: pattern with 10% of pixels lit per row, typical display
3) All power numbers are for LUMA open (no analog dimming)
EL320.240-FA3 Power vs. Percent of Pixels On, for All Three
Luminance Settings, Typical
0
2
4
6
8
10
12
0 20406080100
Percentage of pixels turned on (yellow) per row
Power Consumption, watts
Max luminance, 325 Hz
Med luminance, 240 Hz
Min luminance, 180 Hz
EL320.240-FA3 Operations Manual Page 10 of 25