Philips P89LPC903 Light Therapy Device User Manual


 
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC901/902/903
WATCHDOG TIMER
2003 Dec 8 86
Table 12-2: P89LPC901/902/903 Watchdog Timeout Values
Figure 12-3: Watchdog Timer in Watchdog Mode (WDTE = 1)
PRE2-PRE0 WDL in decimal)
Timeout Period
(in watchdog clock
cycles)
Watchdog Clock Source
400KHz Watchdog Oscillator Clock
(Nominal)
12MHz CCLK (6MHz CCLK/2
Watchdog Clock)
000
0 33 82.5µs 5.50µs
255 8,193 20.5ms 1.37ms
001
0 65 162.5µs 10.8µs
255 16,385 41.0ms 2.73ms
010
0 129 322.5µs 21.5µs
255 32,769 81.9ms 5.46ms
011
0 257 642.5µs 42.8µs
255 65,537 163.8ms 10.9ms
100
0 513 .1.28ms 85.5µs
255 131,073 327.7ms 21.8ms
101
0 1,025 2.56ms 170.8µs
255 262,145 655.4ms 43.7ms
110
0 2,049 5.12ms 341.5µs
255 524,289 1.31s 87.4ms
111
0 4097 10.2ms 682.8µs
255 1,048,577 2.62s 174.8ms
8-Bit Down
Counter
MOV WFEED1, #0A5H
MOV WFEED2, #05AH
WDL (C1H)
PRE2 PRE1 PRE0 WDRUN WDTOF WDCLK
SHADOW
REGISTER FOR
WDCON
WDCON(A7H)
PRESCALER
RESET
control register
Watchdog reset can also be caused
by an invalid feed sequence, or by
writing to WDCON not immediately
followed by a feed sequence
Watchdog
Oscillator
PCLK
÷32