Philips P89LPC903 Light Therapy Device User Manual


 
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC901/902/903
UART (P89LPC903)
2003 Dec 8 63
Figure 8-1: BRGCON Register
Figure 8-2: Baud Rate Generations for UART (Modes 1, 3)
Framing Error
A Framing error occurs when the stop bit is sensed as a logic ’0’. A Framing error is reported in the status register (SSTAT). In
addition, if SMOD0 (PCON.6) is 1, framing errors can be made available in SCON.7. If SMOD0 is 0, SCON.7 is SM0. It is
recommended that SM0 and SM1 (SCON.7-6) are programmed when SMOD0 is ’0’.
Break Detect
A break is detected when any 11 consecutive bits are sensed low. A break detect is reported in the status register (SSTAT).
Since a break condition also satisfies the requirements for a framing error, a break condition will also result in reporting a framing
error. Once a break condition has been detected, the UART will go into an idle state and remain in this idle state until a stop bit
has been received. The break detect can be used to reset the device by setting the EBRR bit (AUXR1.6).
A break detect reset will force the high byte of the program counter to be equal to the Boot Vector contents and the low byte
cleared to 00h. The first instruction will be fetched from this address.
BRGCON
Address: BDh
Not bit addressable
Reset Source(s): Any reset
Reset Value: xxxxxx00B
BIT SYMBOL FUNCTION
BRGCON.7-2 - Reserved for future use. Should not be set to 1 by user programs.
BRGCON.1 SBRGS Select Baud Rate Generator as the source for baud rates to UART in modes 1 & 3 (see
Table for details)
BRGCON.0 BRGEN Baud Rate Generator Enable. Enables the baud rate generator. BRGR1 and BRGR0 can
only be written when BRGEN =0.
76543210
- - - - - - SBRGS BRGEN
÷2
Baud Rate Generator
(CCLK-based)
SMOD1 = 1
SBRGS = 0
SBRGS = 1
Timer 1 Overflow
(PCLK-based)
Baud Rate Modes 1 and 3
SMOD1 = 0