Graco 3A059OG Microscope & Magnifier User Manual


 
Repair
20 3A0590G
Remove Restrictor
1. Note number of turns from open to closed position.
Remove restrictor housing (15) from manifold (1).
2. Place restrictor housing (15) in a vice and remove
nut (16).
3. Unscrew stem (12) clockwise and remove from
restrictor housing (15).
4. Remove and replace o-rings (13, 14).
5. Remove set screw (11) and seat (10) from manifold.
Assemble Restrictor
1. Insert seat (10) with larger tapered end facing up in
manifold (1).
2. Apply blue thread lock to external threads to set
screw (11) and install in manifold.
3. Install o-rings (13, 14) and insert stem (12) into
restrictor housing (15). Turn stem (12) coun-
ter-clockwise until in open position.
4. Loosely install lock nut (16) on stem (12).
5. Tighten restrictor housing (15) into manifold (1).
6. Tighten stem (12) down until it bottoms on seat (10).
Then back stem out to previously noted position or
two full turns and lock in place with lock nut (16).
NOTE: For high volume or high viscosity “B” side
applications, the restrictor parts can be replaced by
a high pressure 3/4 npt plug.
16
15
1
r_258987_3a0590_4a
12
16
15
13
14
r_258987_3a0590_5a
10
11
r_258987_3a0590_6a
10
11
1
13 (black)
14 (white)
12
15
16
r_255684_256980_312749_12a