3.2 Safety system
Since there are rotating knives inside the granulator, there is a built-in safety
system to prevent personal injury.
Emergency stop: The equipment is fitted with an emergency stop switch on the
control panel. The emergency stop is activated by pushing the button. It is reset
by turning the button in the direction of the arrow (anti-clockwise).
Safety switches: The safety system includes 2 safety switches. The switches are
located as follows:
1 by the hopper
1 by the screenbox
The system is designed so that when the screenbox is pulled out a safety switch
is actuated which cuts off the power so that the rotor and screw stop before the
screenbox can be opened.
Similarly, for the hopper, a safety switch is actuated by a loop being pulled out
of the switch and breaking the electric circuit when the locking clamp is