Braun RA300 Mobility Aid User Manual


 
Page 32
H
G
F
E
D
C
B
A
M
M
BATTERY
CHASSIS GROUND
CIRCUIT PROTECTION DEVICE
JUNCTION
MOTOR
COUNTER
MICROSWITCH
RELAY
SYMBOLDESCRIPTION
P1
H
G
F
E
D
C
B
A
J1
NC
NO
C
NC
NO
C
NC
NO
C
86
4
3
1
2
12 GA. OR
12 GA. BK
12 GA. BK16 GA. BL/BK
16 GA. BN/BK
12 GA. BK
12 GA. BK16 GA. OR/BK
16 GA. OR/BK
16 GA. YL
16 GA. OR/BK
16 GA. WH
16 GA. YL
12 GA. BK12 GA. BK
12 GA. RD12 GA. RD
PUMP
"DRIFT IN"
MICROSWITCH
STOW
RELAY
CIRCUIT
PROTECTION
DEVICE
(25 AMP.)
GROUND
BATTERY
RA300 TRANSIT RAMP ASSEMBLY
POWER CONNECTIONS / CONTROL SIGNALS (PROVIDED BY INSTALLER)
SYMBOL KEY
"DRIFT OUT"
MICROSWITCH
DEPLOY
RELAY
COUNTER
16 GA. BN/BK
12 GA. * 12 GA. *
12 GA. *
* RECOMMENDED WIRE GUAGE
GROUND
12 GA. BK
12 GA. BK
12 GA. RD
12 GA. RD
12 GA. RD
12 GA. RD
12 GA. RD
12 GA. RD
12 GA. RD
12 GA. BU
30
87
87A
85
85
86
30
87
87A
NC
NO
C
16 GA. YL/WH
"COUNTER"
MICROSWITCH
85
86
30
87
87A
16 GA. WH
COUNT
N/A POS
NEG
4
3
1
2
USER CONTROL SIGNAL TO STOW RAMP
USER CONTROL SIGNAL TO DEPLOY RAMP
16 GA. *
16 GA. *
SIGNAL TO RAMP STOW INDICATOR
SIGNAL TO RAMP DEPLOY INDICATOR
16 GA. *
16 GA. *
DRAWING SHOWN WITH RAMP IN STOWED POSITION
TROUBLESHOOTING
Electrical Schematic - BF3248Y & BF3748Y