continued
Repeat all previously listed inspection, lubrica-
tion and maintenance procedures at 8 week or
200 cycle intervals (or per vehicle maintenance
schedule).
Consecutive
8 Week or
200 Cycle
Intervals
1 Year
or
1250
Cycles
MAINTENANCE and LUBRICATION
Hydraulic Fluid (Pump) - Check level. Note:
Fluid should be changed if there is visible
contamination. Inspect the hydraulic system
F\OLQGHUKRVHVÀWWLQJVVHDOVHWFIRUOHDNVLI
ÁXLGOHYHOLVORZ
Inspect vehicle-to-ramp wiring harness
Mounting
Decals and Antiskid
Use Braun 32840-QT (Exxon
®
Univis HVI 26)
K\GUDXOLFÁXLGdo not mix with Dextron III or
RWKHUK\GUDXOLFÁXLGV&KHFNÁXLGOHYHOZLWK
ramp deployed fully. Fill to within
µRIWKHERWWRPRIWKHµÀOOWXEHQHFN
Resecure, repair or replace or otherwise correct
as needed
Check to see that the ramp is securely an-
chored to the vehicle and there are no loose
bolts, broken welds, or stress fractures.
Replace decals if worn, missing or illegible.
Replace antiskid if worn or missing.