Braun RA300 Mobility Aid User Manual


 
Page 19
Electrical Connections Illustration
Positive (+) battery
lead wire must be
protected by
installer-provided 30
ampere fuse or
circuit breaker.
Failure to do so may
result in serious
bodily injury and/or
property damage.
W
A
RNING
8-pin Deutsch
Male Plug
(supplied with ramp)
8-pin Deutsch
Connector
(ramp equipped)
An 8-pin Deutsch connector (male
plug) is supplied with the ramp.
The ramp installer provides an ap-
propriate momentary contact control
switch.
Terminate the power supply, ground,
ramp OUT signal and ramp IN signal
DVVSHFLÀHGLQOHJHQG
The Positive (+) “battery” lead wire
must be protected by an in-line
30 ampere fuse or circuit breaker
(installer provided).
BF3248Y & BF3748Y
CONNECTOR - P1
(B.C.# 30136)
TO VEHICLE GROUND
TO USER CONTROL SIGNAL IGNITION/MANUAL RELEASE - BF3248YP ONLY
TO POWER SOURCE - (30 AMP. CURCUIT PROTECTION DEVICE)
TO USER CONTROL SIGNAL TO STOW RAMP
TO USER CONTROL SIGNAL TO DEPLOY RAMP - (MOMENTARY SWITCH)
D
A
G
E
F
C
B
H
TO USER DEPLOY - 16 GA.*
TO USER STOW - 16 GA.*
VEHICLE GROUND - 12 GA.*
POWER SOURCE - 12 GA.*
D
C
B
A
* RECOMMENDED WIRE GAUGE
COLOR
WIRING PROVIDED
BY INSTALLER
PIN
8-COND WIRE CODE
RAMP DEPLOY SIGNAL - 16 GA.*
RAMP STOW SIGNAL - 16 GA.*
PLUG - NOT USED
PLUG - NOT USED
H
G
F
E
BF3248YP
CONNECTOR - P1
(B.C.# 30136)
D
A
G
E
F
C
B
H
TO USER DEPLOY - 16 GA.*
TO USER STOW - 16 GA.*
VEHICLE GROUND - 12 GA.*
POWER SOURCE - 12 GA.*
D
C
B
A
* RECOMMENDED WIRE GAUGE
COLOR
WIRING PROVIDED
BY INSTALLER
PIN
8-COND WIRE CODE
RAMP DEPLOY SIGNAL - 16GA.*
RAMP STOW SIGNAL - 16 GA.*
USER IGN/MAN REL. - 16 GA.*
TO SIGNAL TO RAMP STOW INDICATOR
TO SIGNAL TO RAMP DEPLOY INDICATOR
PLUG - NOT USED
H
G
F
E
Electrical Connections
Figure K
RAMP INSTALLATION
OR