FUNCTION SYMPTOM POSSIBLE CAUSE REMEDY
TROUBLESHOOTING
3.11 See 1.00
'ULIW,Q0LFURVZLWFKRXWRIDGMXVW-
ment or damaged
3.13 Drift In Microswitch harness discon-
nected, damaged or otherwise
damaged
3.21 Ramp was stopped within the Stow
“Drift In” range during Deploy func-
tion ("Y" models only)
3.41 See 2.31, 2.32, 2.34, 2.35 and 2.36
3.42 Stow pressure relief valve setting
too low
3.43 Stow pressure relief valve stuck
open due to contamination or other-
wise damaged
4.51 See 2.40
4.61 See 2.40 and 2.50
4.71 See 2.35, 2.36 and 2.62
$GMXVWRUUHSODFH6HH0LFURVZLWFKHVLQ
Systems Descriptions for details
Connect, repair or replace
Activate Deploy function until ramp is
out of the Stow “Drift In” range. Then
activate Stow function.
$GMXVWUHOLHIYDOYHVHWWLQJ6HH6\VWHPV
Descriptions for details.
Contact Braun Product Support - re-
place pump
3.60
Drifts
Excessively
Slow
(or No Drift)
3.70
Drifts
Excessively
Fast
3.50
Faulty or
Sluggish
Operation
3.40
Pump Runs
But
Doesn’t
Stow
3.10
No
Operation
3.20
Locked in
Intermediate
Position
(No Response to
Stow Switch/No
Drift In)