11. SPECIFICATIONS
11-1. Capacity and minimum display
C02- setting 0* 1 2 3 4 5 6 7
Capacity 6 15 30 60 150 300 600 1500
0.002* 0.005 0.01 0.02 0.05 0.1 0.2 0.5
0.001 0.002 0.005 0.01 0.02 0.05 0.1 0.2
kg
Min. display
0.0005 0.001 0.002 0.005 0.01 0.02 0.05 0.1
Capacity 6000 15000 30000
2* 5 10
1 2 5
g
Min. display
0.5 1 2
NA NA NA NA NA
Capacity 15 35 70 150 350 700 1500 3500
0.005* 0.01 0.02 0.05 0.1 0.2 0.5 1
0.002 0.005 0.01 0.02 0.05 0.1 0.2 0.5
lb
Min. display
0.001 0.002 0.005 0.01 0.02 0.05 0.1 0.2
Capacity 240 560 1120 2400 5600 11200
0.1* 0.2 0.5 1 2 5
0.05 0.1 0.2 0.5 1 2
oz
Min. display
0.02 0.05 0.1 0.2 0.5 1
NA NA
Capacity 15 35 70
lb-
oz
Min. display 0.1 0.1 0.1
NA NA NA NA NA
*: Factory setting NA: Not Available
11-2. Specifications
Input sensitivity 0.2 µV / d (d: the smallest Min. display of kg)
Input signal range 0 mV ~ 13 mV
Load cell excitation
voltage
5 V DC ±5% (no remote sensing)
Load cell drive capacity Up to 4 x 350 ohm load cells
Zero ±(0.2 µV ±0.001% of zero adjustment voltage) / °C (typ.)
Temperature
coefficient
Span ±0.001% / °C of reading (typ.)
Non-linearity ±0.01 % of full scale
Display
7 segment LCD display (Character height 18.6 mm) with backlight
60 segment analog sweep display with backlight
Display update Approximately 20 times per second
Operating temp. -10°C ~ 40°C / 14°F ~ 104°F, less than 85% R.H.
Power supply AC main (100V ~ 240 V, 50/60 Hz) or SLA Battery (option)
Dimension 250 (W) x 202 (D) x 266 (H) mm / 9.8 (W) x 8.0 (D) x 10.5 (H) in.
Weight Approximately 2.7 kg