18 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 September 2007
RTIF1-
070904-003
An incorrect domain state is reported. After
the command sendbreak to domain is issued,
showdomainstatus continues to show the state
as "Running" when the domain is actually at
"ok" prompt.
There is no workaround. This is expected
behavior of the sendbreak operation.
RTIF1-
070904-004
The latest communication field in
showarchiving is not updated regularly.
Disabling and re-enabling archiving refreshes
the Latest communication field in
showarchiving output.
RTIF1-
070904-005
Time can't be synchronized with the NTP
server.
Check the stratum value of the NTP server.
The stratum value of XSCF is "5." The NTP
server which the XSCF refers to must be a
server on which the stratum value is smaller
than 5. When you changed the NTP server to
refer to, reboot the XSCF.
When the stratum value has been set correctly
and the time can't be synchronized, use the
showntp(8) command to check the jitter value
to be displayed.
If this value is large, please reboot the XSCF.
RTIF1-
070904-006
While executing the domain power-on,
domain reset or DR, in case the XSCF reboot
occurred, the process may be aborted in some
or all of the XSB.
Execute the domain reset one more time, or
power off the domain and then power on
again.
RTIF1-
070912-001
If an invalid SMTP server is configured, a
subsequent attempt to disable email service
(using the setemailreport CLI) may block for
up to 30 minutes.
Wait for the CLI to complete. The rest of the
system will function normally during this
time.
The CLI can also be aborted by ^C. Note that
the operation (disabling emailreport) is
completed, even if ^C is used.
showemailreport can be used to confirm
that the service has been disabled.
RTIF1-
070914-001
While executing the firmware update by using
the flushupdate(8) command or BUI, when
the import of XCP executed by using the
getflushimage(8) command or BUI, the
firmware update aborts.
Do not execute the import of XCP by using the
getflushimage(8) command or BUI, while
executing the firmware update.
RTIF1-
070914-002
When the XSCF switching performed, the
monitor message doesn't show the number of
XSCFU which turned Active.
Execute the
showhardconf(8) command to
refer to the state of XSCFU.
RTIF1-
070914-003
When the XSCF switching performed, there
may be "SCF: Board control error (DMA
timeout)" stored in the error log.
None available at this time.
This message can be safely ignored.
TABLE 5 XCP Issues and Workarounds (Continued)
ID Description Workaround