Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplier. An over temp
indicator LED on the front panel of the amplier lights red whenever the recommended
operating temperature has been exceeded. See “Front Panel Features and Operation”
on page 9.
To reduce the chances for an over temp condition, the XPAs should be arranged in a
rack environment so that adequate airflow is available both above and below the XPA
whenever possible. No more than two XPAs should be arranged one-on-top-of-the-other
in a rack without an open space between them, as shown in the following illustration. An
XPA can also be arranged above or below another non-XPA device, but there must be an
open space both above and below those devices.
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Figure 4. Allow Sufficient Spacing for Adequate Ventilation
Flexible Conduit Adapter Kit Installation
WARNING: Failure to follow these instructions may result in serious injury.
The circuit breaker used for this connection should be rated no lower
than 20 amps and no greater than 30 amps.
This unit must be installed in accordance with the National Electrical
Code and with all local codes.
An ALL-POLE MAINS SWITCH with a contact separation of at least
3 mm in each pole shall be incorporated in the electrical installation of
the building. The installation shall be carried out in accordance with all
applicable installation rules.
Installation and service must be performed by a qualified electrician only.
ATTENTION: Failure to follow these instructions may result in damage to the
unit.
A UL listed electrical distribution box is recommended for the
termination of the conduit opposite the XPA. See the following
“UL Requirements” section on page 7.
The optional Flexible Conduit Adapter Kit (Extron part #70-228-02) consists of
• One EMT adapter plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
• One UL rated zip tie wrap
• Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires
XTRA Series • Installation 6